SPECTRUM - UVC DISINFECTION ROBOT

360 SENSOR TECHNOLOGY

No more handling of hazardous chemicals is required to clean surfaces
SPECTRUM-R

500W to 1000W

UVC DISINFECTION ROBOT

SPECTRUM-C

500W to 1000W

UVC DISINFECTION

SPECTRUM-E

100W to 200W

UVC DISINFECTION

No more handling of hazardous chemicals is required to clean surfaces when the SPECTRUM is deployed. In today’s continuously changing environments it has become even more important than ever to effectively protect from the various infectious microbes.

SPECTRUM is a high-output UV disinfection robot using unique room mapping technology to deliver a fast and effective germicidal dose of continuous wave UVC energy killing germs and pathogens when and where you want. SPECTRUM is intelligent and completely removes the guess work and ineffectiveness of regular cleaning. The SPECTRUM will deliver exactly this protection to its users by efficiently and effectively eradicating harmful microbes on surfaces and in the air with the use of UV energy.

SPECTRUM is the latest constant wave UV-C surface and air disinfection technology designed specifically for all areas of the hospital and healthcare environment. SPECTRUM incorporates unique patented design features that reduce shadowing. Log 6 reduction (99.9999%) bacterial kill achieved in minutes.

The SPECTRUM-C is completely mobile, making it perfect for disinfecting ambulances and suitable for disinfecting patient rooms, operating theatres and all over the hospital, including the smallest of spaces. SPECTRUM Smart UVC is the portable UV disinfection system that precisely measures reflected UVC emissions with 360Sensor to automatically deliver the pathogen-lethal UV dose required for each room, dynamically compensating for room size, shape and other dose altering variables such as the position of contents, windows, blinds and doors.

  • SPECTRUM uses narrow band UVC light for a high efficiency targeting of the DNA-disrupting wavelength that stops pathogens.
  • SPECTRUM is safe to use in rooms with glass windows and doors. UVC is not transmitted through glass windows.

Target Dose Chart to Deactivate Germs

Microorganism D99% Dose Required (micro watt-sec) Time to reach D99 Dosage in Minutes Direct Distance to Surface in feet
VIRUS 5FT 10FT 15FT
Influenza A (flu) 4,558 2 3 5
Coxsakievirus (hand , foot, mouth disease) 16,250 5 10 15
Herpes Simplex 7,453 3 5 10
BACTERIA
methicillin-resistant Staphylococcusaureus 7,106 3 5 10
Carbapenem-resistant Klebsiella pneumoniae 11,000 4 7 12
Escherichia coli(E-coil) 3935 1 2 4
FUNGAL SPORES
Cladosporiumspores 121,188 30 50 80
Aspergilli'sNiger spores 317,598 70 120 225
CandidaAlbian's 81,554 20 30 60

The SPECTRUM can be used for the following environments or wherever microbial disinfection is required:

  • NURSING HOMES
  • OUTPATIENT SURGERY CENTERS
  • PHYSICIANS OFFICES, AMBULANCE
  • PATIENT ROOMS, WAITING ROOMS
  • TESTING LABORATORIES
  • VENTILATORY CLINICS & KENNELS
  • PASSENGER FLIGHTS AND BUS AND TRAIN
  • SCHOOLS-CLASSROOMS, FOOD PROCESSING
  • DETENTION CENTERS, HOMELESS SHELTERS
  • SHOPPING COMPLEX, MOVIE THEATERS
  • HOTEL ROOMS, LOCKERS ROOMS
Construction Materials 304 Stainless steel
Lamp Type – UV-C LED
LED Driver Inbuilt
Lamp Length 1.2Meter
Footprint 200mm diameter
Lamp life 20000 hours continuous operation
Power Source 120/230 VAC, 50/60Hz
Power ON Indicator Illuminated Switch
Power Rating: 100W/200W/500W/1000W
Delay timer to turn unit ON 5 seconds delay
Power Interruption Memory Device will resume operation after set point
Operation Modes Indicated by LED
Motion sensors (safety) 360 degrees
Operating Environment Indoor 40°F to 135°F, 0-95% RH
Metal reflectors to protect lamp and better distribute UV energy
Tri-color LED indicates status of operation
Optional Inbuilt Battery 6 Hours Backup
Four (4) high output extended length UVC Teflon coated lamps.
Built in mast handles for help in moving the unit.
Digital Timer/Counter to set actual sanitizing cycle time up to 99 hours.
Six infrared motion sensors to automatically shut off device if someone enters the room during the disinfection cycle.
Built in aluminum reflectors to direct light to hard to reach areas such as corners, ceilings and floor surfaces.
Four wheel design to make it easy to transport the device from room to room. One wheel castor can be locked in place.
Tri-color LED indicates status of operation.
Four maximum output extended length UV-C LED with combined output of 100W/200W/500/1000 watts.
Digital timer/counter to set disinfection cycle times of up to 99 hours.
Optional Inbuilt Battery 6 Hours Backup
Remote Operation With the Smartphone
Optional Charging By Solar Panel

UV SAFETY

Ultraviolet (UV) MPE’s Maximum Permissible Exposure
UV REGION WAVELENGTH MPE(MAXIMUM PERMISSIBLE EXPOSURE)
UV-A 315 - 400 nm 1mW/cm2 8 hrs
UV-B 285 - 315 nm 500 uW/cm2 1 min
UV-C 100- 285 nm 100 uW/cm2 1 min

UV DOSE

UV light can inactivate waterborne infectious organisms but there is an important detail to understand: That is the concept of UV dose. UV dose is a calculation that consists of three variables:

  • The speed of the fluid moving past the lamps. This speaks to “contact time”
  • The transparency of the fluid to UV light (transmittance). This is called UVT or T10
  • The power of the UV light emitting from the lamp expressed in Wm2

UV TECHNOLOGY

dhonaadhi

LEDS ARE HIGH POWER DENSITY UV SOURCES

  • MORE PHOTONS PER SURFACE AREA
  • SMALLER LAMP FOOTPRINT
  • SMALLER UV SYSTEM
  • LONG LIFE TIME
  • LOW ENERGY CONSUMPTION
  • EASY TO CONTROL THE DOSE
dhonaadhi dhonaadhi

UVC is proven to kill all known pathogens at 250nm -280nm.

SPECTRUM-C is proven to destroy some very infectious pathogens over a rapid disinfection cycle, including Enterococcus, MRSA, C.difficile and Ebola.

dhonaadhi